Parker instrument tube fitting installation manual. For chemical compatibility, refer to the product specifications table on this page and the fluid compatibility guide. Parker tube fittings are available with several types of parallel. Videos instructing on the process of coning and threading of tubing, either by way of our model aegctm coning and therading machine or by manual hand tools process.
Instrument tube fitting installation manual parker hannifin. Transair pipe should be protected from mechanical impact, particularly if exposed to collision with forklift trucks or when sited in an environment with moving overhead loads. Sep 22, 2020 reference our detailed assembly instructions in the assembly installation section in the parker catalog 4300. General prior to the installation of a transair compressed air distribution system, the installer should ensure that the installation area complies with any regulations applicable to areas exposed to explosive hazards in particular the effect of static electricity in a silo area. In cases where a male or female pipe thread is the second end of a parker cpi alok fitting, such threads may be the pressure limiting factor of the tubing system. Watch the quickfit installation video to see the ease of installation. Transair new aluminium products have been especially designed to reduce the space needed, the number of fittings and the time of installation required while proposing a largest range in term of diameters and shapes. Parker chelsea products division 8225 hacks cross road olive branch, ms 38654 contact division. Instrument tube fitting installation manual bulletin 4200b4 september 2009.
To flare the tube end, consult your flaring tooling manual. The minimum and maximum temperature limits of the connection style and materials listed in the valve, fitting and tubing catalog. An installers pocket guide for swagelok tube fittings ms. Installation instructions caps and plugs caps see swagelok tube fitting installation and reassembly, page 12 and 14. Detailed instructions for proper assembly and installation of orfs hydraulic fittings. Insert the tube into the fitting until it is fully. Double and singleferrule instrumentation tube fittings. Parker s a lok fittings are designed as leakfree connections for process, power and instrumentation applications.
Ensure that the correct oring is properly installed in the groove of the fitting, if not already preinstalled by the fitting manufacturer parker provides seallok fittings with preinstalled o. Valves, fittings and tubing parker autoclave engineers. Reusable hose fitting installation using expert advice. Fittings are available in brass and stainless steel. Trueseal fittings with metal gripper collets can be used with tubing listed above and soft copper tubing. For stainless steel or glass tubing or all other metal tubing, consult factory. With a few components, you can get the quickfit system installed on your machinery in short order.
Instructional videos for parker autoclave engineers a global manufacturer of high pressure valves, fittings, tubing, and airdriven liquid pumps. The table below shows the proper flare dimensions for jic fittings. The parker design and installation guide sets forth the recommended practices to the professional gas service installer and other trade professionals in the application of the csst. Parker autoclave engineers medium pressure fittings, nicknamed slimline sf, are designed for use with sm series valves and parker autoclave engineers medium pressure tubing. With strategic alliances, multiyear contracts and inventory maintenance agreements, team technical services has built a bridge of trust between our customers, the sales and management team, and our suppliers. Tapered thread port assembly and installation instructions. The quickfit system provides a solution that combines incredible ease of use with complete functionality. Several important features make this dependable service possible under widely varying conditions. Seven parker fountain pen repair manuals, from 1920about 1960. Routine maintenance oil changes can bring a multitude of challenges.
An installers pocket guide for swagelok tube fittings ms151. Table of contents catalog 4300 pdf section updated october 2017 assembly installation parker hannifin corporation tube fittings division columbus, ohio. The minimum length between tube fitting and tube bend v. Parker s polytite fittings are compact, preassembled compression. Completed parker autoclave engineers high pressure connection. Tools, installation, operation, maintenance parker autoclave. Parker s comprehensive range of hydraulic fittings fulfills todays application requirements as well as state of the art safety and quality needs. Parker tube assembly instructions technical download front cover. Accomplish this connection by screwing female hexagon fitting onto male threaded fitting. Installation instructions swagelok hydraulic swaging unit for installing larger size swagelok tube fittings n must be used to install 1 14, 1 12, and 2 in and 28, 30, 32, and 38 mm swagelok tube fittings n is available to install 12 to 1 in. Manually with the fitting body or hardened pre assembly tool. Parker industrial tube fittings europe catalog 41009uk exotic. A heavy wall thickness resists ferrule action more than a thin wall. Experience has shown that breakdowns, retightening and leaks can be avoided by following these safety instructions.
The swagelok tube fitters manual balances theory and practical examples making it a musthave reference for fluid system engineers, designers, and technicians, as well as students. The recommended practices apply only to parker csst. Proper assembly steps for 37 flare fittings using the flats. Assembly instructions for parker eo3 metric flareless tube fittings assembly of eo3 tube fittings is complete when the marking on the indicator rings of the stud and nut align. The go no go gauge gauge is simple to use it is safe and reliable but, more importantly, it ensures that installation is right first time, every time. Indicator rings save the last assembly position on the nut and the marking will indicate proper assembly. Parker instrument tube fittings are sold completely assembled and ready for immediate use. Tube fabrication tools, including flaring tools, are available from parker catalog 4300 section s. A carefully assembled parker tube fitting will provide a sealed joint. Parker s preassembly tool is an easytouse manual tool to ensure the correct preassembly of compression tube fittings on instrumentation tubing. This video shows the assembly process of parker psr progressive stop ring fittings. Refer to parker autoclave engineers valve, fitting and tubing catalog installation section for proper tubing connection installation.
P3580 step 1, 2 completed parker autoclave engineers medium pressure connection. Gather required tools and materials for the project. Catalog 4400 us 42 series fittings use with 422, 431, 436, 482tc, 482st hoses. Maintenance becomes simple, productivity goes up, and the. While holding the fitting body steady, follow swagelok tube fitting installation instructions, page 12. The tool is designed to be clamped in a benchmounting vice for assembly. Jul 09, 2018 wrench tighten the connector to the appropriate turns that are recommended in the assembly and installation section of the parker catalog 4300. The eopsr fitting produces high pressure, leak free connection of tube. Stepbystep hydraulic hose assembly parker hannifin. Fittings and tubing parker autoclave engineers fcd. Over 60 years of combined experience in the valve and fitting industry. Parker or its subsidiaries or authorized distributors. Installation instructions for parker autoclave engineers speed bite compression fitting connection. Cramped engine compartments make access difficult and can lead to safety and ergonomic risks for workers.
Under or over tightening may result if you deviate from this range. Coning and threading kits coning and threading kits parker autoclave engineers manufactures a manual. Parker eo3 metric flareless tube fittings assembly. Connect diss female hexagon fitting see fig 18 of the nitrous oxide hose to male diss fitting on the back of the analgesia head see fig 19. Videos instructing on the process of coning and threading of tubing, either by way of our model aegctm coning and therading machine or by manual. For 116, 18, and 316 in 2, 3, and 4 mm tube fittings. A critical step in the assembly process is aligning the tube end with the connecting fitting face.
Binder, or the parker instrument tube fitting installation manual bulletin 4200b4. Our fittings are specifically designed to perfectly match with the respective hose types for superior service life and leak free operation. Thus, proper installation is critical for troublefree operation. Parker thermoplastic fittings and valves are specifically designed to handle water and beverage industry applications.
Parker s comprehensive range of fittings and quick couplings will keep your application up and running with reliableleak free connections that outperform in the toughest environments. Instrument tube fitting installation manual instrument tube fitting. Normally the total number of tapered threads engaged should be between 312 and 6. Assembly instructions and videos can also be found on. For 116, 18, and 316 in 2, 3, and 4 mm tube fittings, tighten the plug oneeighth turn.
Gaugeable tube fittings and adapter fittings ms01140. Manual makeup and installation instructions for quick set system qss only 1 4. Esma group has been in existence since 1973 in the uae. Parker autoclave engineers instrumentation products.
Installation no adjustments are necessary prior to installation. Parker autoclave has available the tooling and instructions needed for safe and reliable operation of our products. For any support, please contact at pscs vietnam co. Oring face seal tube end assembly instructions for.
Warning the information contained within this publication is intended for educational purposes only. For more than 40 years forberg has been a leader in instrumentation and the industrial. This multiple choice training concept from tube fittings division europe, in addition to the regular. Sep 06, 2018 improper flaring or installation causes over half of the leakage with flared fittings. Parker eo3 metric flareless tube fittings assembly instructions. Gaugeable tube fittings and adapter fittings 3 tube straight fittings fittings unions union, 14 reducing union, 15 bulkhead union and bulkhead reducing union, 16 male connectors n pt, 17 isobsp tapered thread rt, 18 isobsp parallel thread rs, 19 isobsp parallel thread rp, 20 bulkhead npt, 21 saems straight thread st and long. Monitored dial mixer nitrous oxide oxygen mixer for dental analgesia. Read more product information tools manual coning and. See swagelok tube fitting installation and reassembly, page 12 and 14. Poster introducingtransair new aluminium products for technical rooms.
They are suitable for conveying water, beverages, food, co 2, air, and dyes. For the most successful connection for gas service, all installation instructions should be followed carefully and the heavier permissible wall thickness of tubing should be selected. In this video, you will learn to use parkers polytite fitting. Better appearance tubing permits smoother contours with fewer fittings for a professional look to tubing systems. No torque is transmitted to tubing during installation. Plugs while holding fitting body steady, tighten the plug onequarter turn from the fingertight position. Tube fittings are designed to provide a leaktight seal for pressures up to the suggested allowable pressure rating of the tubing. For more than 40 years forberg has been a leader in instrumentation and. Each of 11 chapters covers a different aspect of a tubing system, including fittings, tubing, installation, and more. For the 37 flare fitting, the flats method of installation is recommended because it is more forgiving than the torque method. Includes details of tools, and detailed instructions for working on duofolds, vacumatics, 51s, 45s, 75s, pencils, and more. May 02, 2017 to 0025223 technical manual integrated pressure systems and components portable and installed f0960389d3074 distribution statement a approved for public release. To the extent that parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications. They incorporate conedandthreaded connections with the orifice sized to match the highflow 15,000 psi tubing options shown later in this brochure.
Polyethylene line stoppingoperating instructions manual for shur stop pe line stopping system form 262operating instructions manual for 6 8 sdr 11 11. Twoferrule, mechanical grip design the two ferrules separate sealing and tube gripping functions. The gripping ring of each fitting is then automatically secured and the connection is safe. Parker autoclave engineers manufacturers products to operate under extreme pressure and temperature conditions. Tube fitting installation manual bulletin 4200b4 revised, july 2004. These precision quality manual tools permit onsite end preparation for. Manual assembly tool, preassembly tube fittings parker na. Tighter joints quality tube fittings, correctly assembled, give better assurance of leakfree systems. Parker s 24 flareless tube fittings, ferulok, have a visible bite which allows the fitting assembler to visually inspect the bite quality, which significantly minimizes the risk of improper assembly and related service problems in hydraulic connections. Installation instructions installation guides with videos pipe 1216. It allows the end user to check that the correct turns of the nut are made and can also ensure that the tube is fully bottomed within the fitting. No matter what your application, we have the fittings and couplings to help you avoid costly downtime. Fewer fittings mean fewer joints, fewer leak paths.
Poster transair new aluminium products for technical rooms postt005. The world leader in high pressure valves, fittings and tubing manual needle valves parker autoclave engineers valves are designed to operate safely and reliably at pressures to 150,000 psi 10342 bar. Parker will provide stepbystep instructions based on your machinerys make and model. Parker s quickfit oil change system makes oil changes for engines and machinery a faster, cleaner, and safer process. Parker autoclave engineers is a member of the instrumentation products divison of parker hannifin, a global manufacturer of high pressure valves, fittings, tubing, and airdriven liquid pumps. Manually with the fitting body or hardened preassembly tool. Parkers preassembly tool is an easytouse manual tool to ensure the correct preassembly of compression tube fittings on instrumentation tubing. Pressure ratings for pipe ends are shown on page 79. This handsonbooklet is an excellent reference tool for the installer of instrumentation tube fittings. Information contained within is not intended for resale and may not be reproduced in whole or in part without the express written consent of the parker hannifin. The video shows the function and assembly of eo2 fittings.
517 767 317 478 1228 968 506 415 946 437 1228 791 1523 74 94 1143 703 1143 437 1406 1356 840 799 1275 626 122 60 1389 820 391 653 1095